  Tailored solutions for the detection and extinguishing of fires Banner


Central Unit, Type: BMLZ 1012

P/N: 80260
Produktbild - Central Unit

 
 
Downloads

E-mail request for this product 
 
e-mail:  
your name:  
company:  
street:  
zip code, city:  
country:  
message:  
Captcha Code
Description

Suitable for net-extinguishing volumes of 0.35 m³ to 225 m³ (1 to max. 16 fire extinguishing generators).
Automatic or manual activation of fire extinguishing generators.
Fire detection by max. 8 Fire Detectors of Co. EGON HARIG GmbH.
Initiation criterion variable, also possible the 2-line dependency *.
Adjustable trigger temperatures for Heat Detectors (60 ° C, 90 ° C, 120 ° C, 180 ° C) *.
Variably adjustable time lag before activation of fire extinguishing generators*.
As a two-shot system (automatic or manual post-extinguishing) adjustable *.
VDS-compatible interfaces *.
Potential-free messages Fault and Alarm.
The system is ready for use again after replacing the fire extinguishing generators.

* These values will be preset at the factory fixed by appointment.

 
 
Technical data

 Dimensions (l x w x d)220 mm x 138 mm x 55 mm
 Housing materialPolystyrene
 Weight550 g
 Protection typeIP 20
 Operating temperatures-10 °C to 60 °C
 Operating voltage24 V DC
 Operating current0.2 A
 Release currentmax. 4 A

 

 
Matching accessories
AEROSOL Fire Extinguishing Generator Dynameco 50-E03
 
Description
AEROSOL Fire Extinguishing Generator with electrical ignition. • Effective fire fighting on site • Non-toxic extinguishing agent: AEROSOL • Period of use: max. 5 years These fire extinguishing generators produce after an electrical ignition an environmentally friendly, non-toxic AEROSOL. The energy of the fire will be reduced. And by the binding of free radicals, the flame will be extinguished. During this process, the environment is not deprived of oxygen. This product class is approved for fire protection classes B (limited) and C. These fire extinguishing generators are particularly suitable for fighting of incipient fires. They are used for room-based and object-based fire extinguishing. For the release of these fire extinguishing generators, a central unit for fire detection and fire extinguishing is necessary with the appropriate fire detectors (e.g. UV-Flame Detectors, Temperature-Fire Detectors, Heat Detectors, Smoke Detectors, Manual Release Push Buttons, ...).
AEROSOL Fire Extinguishing Generator Dynameco 200-E02
 
Description
AEROSOL Fire Extinguishing Generator with electrical ignition. • Effective fire fighting on site • Non-toxic extinguishing agent: AEROSOL • Period of use: max. 5 years These fire extinguishing generators produce after an electrical ignition an environmentally friendly, non-toxic AEROSOL. The energy of the fire will be reduced. And by the binding of free radicals, the flame will be extinguished. During this process, the environment is not deprived of oxygen. This product class is approved for fire protection classes B (limited) and C. These fire extinguishing generators are particularly suitable for fighting of incipient fires. They are used for room-based and object-based fire extinguishing. For the release of these fire extinguishing generators, a central unit for fire detection and fire extinguishing is necessary with the appropriate fire detectors (e.g. UV-Flame Detectors, Temperature-Fire Detectors, Heat Detectors, Smoke Detectors, Manual Release Push Buttons, ...).
AEROSOL Fire Extinguishing Generator Dynameco 300-E02
 
Description
AEROSOL Fire Extinguishing Generator with electrical ignition. • Effective fire fighting on site • Non-toxic extinguishing agent: AEROSOL • Period of use: max. 5 years These fire extinguishing generators produce after an electrical ignition an environmentally friendly, non-toxic AEROSOL. The energy of the fire will be reduced. And by the binding of free radicals, the flame will be extinguished. During this process, the environment is not deprived of oxygen. This product class is approved for fire protection classes B (limited) and C. These fire extinguishing generators are particularly suitable for fighting of incipient fires. They are used for room-based and object-based fire extinguishing. For the release of these fire extinguishing generators, a central unit for fire detection and fire extinguishing is necessary with the appropriate fire detectors (e.g. UV-Flame Detectors, Temperature-Fire Detectors, Heat Detectors, Smoke Detectors, Manual Release Push Buttons, ...).
AEROSOL Fire Extinguishing Generator Dynameco 2000-E02
 
Description
AEROSOL Fire Extinguishing Generator with electrical ignition. • Effective fire fighting on site • Non-toxic extinguishing agent: AEROSOL • Period of use: max. 5 years These fire extinguishing generators produce after an electrical ignition an environmentally friendly, non-toxic AEROSOL. The energy of the fire will be reduced. And by the binding of free radicals, the flame will be extinguished. During this process, the environment is not deprived of oxygen. This product class is approved for fire protection classes B (limited) and C. These fire extinguishing generators are particularly suitable for fighting of incipient fires. They are used for room-based and object-based fire extinguishing. For the release of these fire extinguishing generators, a central unit for fire detection and fire extinguishing is necessary with the appropriate fire detectors (e.g. UV-Flame Detectors, Temperature-Fire Detectors, Heat Detectors, Smoke Detectors, Manual Release Push Buttons, ...).
Heat Detector TF 180-9
 
Description
Suitable for fire detections. Fast response, because low sensor mass. “Alarm”-set point (variable*) max. 180 °C * The temperature at which an alarm should be triggered, will be set up fixed in the Fire Detection and Extinguishing Panel or in the Evaluation Unit of the Temperature-Measurement and Extinguishing-Agent-Release System.
Heat Detector TF 180-RB
 
Description
Suitable for fire detections Robust design Water- and dustproof Fast response, because low sensor mass “Alarm”-set point (variable*) max. 180 °C * The temperature at which an alarm should be triggered, will be set up fixed in the Fire Detection and Extinguishing Panel or in the Evaluation Unit of the Temperature-Measurement and Extinguishing-Agent-Release System.
Heat Detector TF 180-BA
 
Description
Suitable for fire detections Robust design Water- and dustproof Connection cable shielded Fast response, because low sensor mass “Alarm”-set point (variable*) max. 180 °C * The temperature at which an alarm should be triggered, will be set up fixed in the Fire Detection and Extinguishing Panel or in the Evaluation Unit of the Temperature-Measurement and Extinguishing-Agent-Release System.
Sounder with Flash Light CH / 100 AV / SDR / EH
 
Description
39 adjustable signal toones removable screw terminal
Optical Smoke Detector ECO 1003
 
Description
Low profile design Low current draw Automatic drift compensation Easy Maintenance Various Mounting Bases The detector can be used in combination with the mounting base ECO 1000 BREL 24L as a line detector or with the mounting base ECO 1000 BREL 24L EH as end- or single detector.
High Temperature Thermal Detector ECO 1004T
 
Description
Low profile design Low current draw Easy Maintenance Various Mounting Bases The detector can be used in combination with the mounting base ECO 1000 BREL 24L as a line detector or with the mounting base ECO 1000 BREL 24L EH as end- or single detector.
Control Panel BED 1012 LU
 
Description
Suitable for Central Units of types: BMLZ 1012, 1012A
Control Panel BED 1012 G
 
Description
Suitable for Central Units of types: BMLZ 1012, 1012A
UV-Flame Detector FL 80/1A...
 
Description
The UV-Flame Detector reacts only upon the short wave part of the UV range (UV C 200 nm to 280 nm, where by the highest sensibility is between 210 +/ 10 nm) of an optical radiation of an open flame. Thus, an influence generally caused by embers and bulbs and at respective sensibility adjustment against solar radiation, special fluorescent lamps and discharge sparks will be avoided. Generating of the voltage for the detector tube will be continuously monitored. In a case of failure this will be signaled. Default factory configurations of the „Alarm“-messages: 1. Quiescent current principle (relay is energized normally and falls in alarm from); 2. Working current principle (relay is de-energized in normal case and draws on alarm at); 3. Continuous alarm (relay is energized: the alarm remains active until power to the detector will be switched off.); 4. Temporary alarm (relay is energized: the alarm will be reset automatically according to the setting (alarm duration up to 95 seconds).); 5. Post-trigger mode (The detectors alarm as long as a fire is detected.)